CR084 04.09.17 EasyBalise/V22 New Start-Up Feature: The application can be
startet directly by opening a LEU programming
file of SIEMENS or Thales ending with the
extensions .sdo or .txt.
implemented
in version 2.4
CR083 04.09.17 EasyBalise/V22 For reasons of consistency in the list of variable,
„value“ and „metaphor“ have been exchanged
for he following variables: NID_RADIO (new
metapher „16 Digits BCD“ instead of „64 Bit“),
X_TEXT (new metaphor "Chars according ISO
8859-1"), NID_XUSER in Packet 44 („Hex“),
NID_OPERATIONAL (new metaphor „8 Digits
BCD“), NID_NM (new metaphor „8 Digits BCD“)
implemented
in version 2.4
CR082 04.09.17 EasyBalise/V22 The variable NID_CTRACTION was not shown in
correctly in the packets 11, 39, 70 and 207.
Instead of starting with the value 0 it startet at
the value 1.
implemented
in version 2.4
CR081 26.07.17 EasyBalise/V22 A graphical presentation of packet 65 TSR has
been implemented for better visualisation of
data
implemented
in version 2.4
CR080 26.07.17 EasyBalise/V22 A new function has been added which converts
telegram files (tlg) to harmonized tlg format
with filename according the the Balise ID.
implemented
in version 2.4
CR079 26.07.17 EasyBalise/V22 A new function has been added which converts
telegram files (tlg) to decoded csv formatted
data.
implemented
in version 2.4
CR078 22.06.17 EasyBalise/V22 The unit of the variable T_VBC in the packet 6 is
wrong in the list presentation. It should be
“days” and not “sec”. In the editor of the packet
6 it is shown correctly.
implemented
in version 2.4
CR077 10.04.17 EasyBalise/V22 Names of variables of Packets 3 and 203 have
been changed to make it easier to read.
implemented
in version 2.4
CR076 22.02.17 EasyBalise/V22 Automatic scaling of Graphs P21, P27 and P55 implemented
in version 2.4
CR075 17.09.16 EasyBalise/V22 There was a failure found in the encoder in one
of the stopping condition called „off-synch-
parsing“.
The condition now has been changed to fulfil the
needs of the specification
implemented
in version 2.4
CR074 28.03.16 EasyBalise/V20 New Variables or ERA Version 1.9 implemented implemented
in version 2.2
CR073 28.03.16 EasyBalise/V20 Upgrade from SRS 3.2.0 to SRS 3.5.0 New
packets 0, 6,180, 181, 200, 206, 207, 239 and
Packet2 to track as well as Message 32
implemented
in version 2.2
CR072 28.03.16 EasyBalise/V20 D_VALIDNV value “now” shound not be
selectable
in M_VERSION =1 (SRS 2.3.0.d)
implemented
in version 2.2
CR071 28.12.15 EasyBalise/V20 Possibility of import and comparison of P44 ZUB
with an external WORD file removed.
implemented
in version 2.2
CR070 28.12.15 EasyBalise/V20 Reading MSTT LEU files from Siemens resulted
in
wrong data presentation.
Now the import also of MSTT files is possible
implemented
in version 2.2
CR069 28.12.15 EasyBalise/V20 Adding or deleting packet to messages to track
is
not possible.
implemented
in version 2.2
CR068 07.06.15 EasyBalise/V18 Correction of Packet 72 Text messages
The variable L_TEXTDISPLAY can now be set to
unlimited by y simple checkbox
implemented
in version 2.0
CR067 07.06.15 EasyBalise/V18 The main user interface has redesigned and
extended with additional Quick_info-Panels
Then window now also can be zoomed.
implemented
in version 2.0
CR066 07.07.15 EasyBalise/V18 In the list of the predefinied values of M_NVKR
the entry “300m” is missing. This leads to a
wrong coding of all following values.
This applies to the Packet 3 and packet 203
implemented
in version 2.0
CR065 07.07.15 EasyBalise/V18 Section of different SSP’s having the same
Speed are not visible in the SSP graph since
they
overwrite each other (the Basic SSP is the last
one which is on the top layer).
The Graph is modified an extended with
additional arrows showing the starting point of
each SSP
section.
implemented
in version 2.0
CR064 07.06.15 EasyBalise/V18 Change position (order) of packet within
telegram was not possible. Two new buttons
have been created to modify the position of each
packet within a telegram or a
message.
implemented
in version 2.0
CR063 06.04.15 EasyBalise/V18 Packet 131 edit dialog cannot be started from
main menu.
implemented
in version 2.0
CR062 11.01.15 EasyBalise/V16 Decoding of NC_TRAIN was wrong and has been
corrected (Value 1 was skipped)
implemented
in version 1.8
CR061 11.12.14 EasyBalise/V16 New Interface with Siemens TPG-V2 with
Bluetooth connection
implemented
in version 1.8
CR060 09.12.14 EasyBalise/V16 Wrong indication of packetlist and tooltip in main
window under certain circumstances.
implemented
in version 1.8
CR059 28.8.14 EasyBalise/V14 The visualisation of the variable Q_FRONT in the
Packet 27 graph was wrong in all previous
versions!
implemented
in version 1.6
CR058 20.3.14 EasyBalise/V14 New Print button in Telegram/Message details
form and additional line with MD4 code in
Logdata listing.
implemented
in version 1.6
CR057 20.3.14 EasyBalise/V14 The new LEU viewer allows the import of LEU
files of SIEMENS and THALES format and the
presentation of the corresponding data.
implemented
in version 1.6
CR056 2.3.14 EasyBalise/V14 New presentation of the graphics (charts) of
packets
21, 27 and 51
implemented
in version 1.6
CR055 2.2.14 EasyBalise/V14 For each telegram, the value of NID_C shall be
presented by a corresponding country-banner.
implemented
in version 1.6
CR054 4.8.13 EasyBalise/V13 EasySignum Application integrated in EasyBalise implemented
in version 1.4
CR053 27.07.13 All ETCS Tools NID_XUSER and NID_NTC values updated
according
ERA_ERTMS_040001, V1.12 22/03/2013
implemented
in version 1.4
CR052 25.07.13 All ETCS Tools NID_CTRACTION and M_TRACTION values
updated
according ERA_ERTMS_040001, V1.12
22/03/2013
implemented
in version 1.4
CR051 25.07.13 All ETCS Tools NID_ENGINE values updated according
ERA_ERTMS_040001, V1.12 22/03/2013
implemented
in version 1.4
CR050 27.07.13 All ETCS Tools NID_C values updated according
ERA_ERTMS_040001, V1.12 22/03/2013
implemented
in version 1.4
CR049 25.07.13 EasyBalise/V13
EasyZUB
ZUB_Light
For ZUB Telegramm NID_XUSER=2 the
relationship
between signal aspect and M_MCOUNT has
been
defined and implemented
implemented
in version 1.4
CR048 12.07.13 EasyBalise/V13 If there is a packet 44 with a unknown
NID_XUSER Number, the content of the P44 data
can not be analysed more in detail. There is an
error message prompted. The user can not
modify the P44 if e.g. only the NID_XUSER is
wrong.
The application shall be modified in a way, a
wrong or not (yet) existing the NID_XUSER can
ot prevent of editing the packet.
implemented
in version 1.4
CR047 07.07.13 EasyBalise/V13 The performance of the encoding process could
be increased significantly by replacing two
iterations of 16 x 117 = 1872 with one single
interation with 1024 loops. (time savings about
40% in the average)
implemented
in version 1.4
CR046 06.07.13 EasyBalise/V13 Dialog for saving tlg files shows empty filename.
The application shall make a proposal for a
filename.
implemented
in version 1.4
CR045 24.06.13 EasyBalise/V13 Vailidation tests of SCMT Telegrams showed
different failures in the decoding respectively
interpretation of the variables (see below)
implemented
in version 1.4
CR044 04.06.13 EasyBalise/V13 The end bracket in the text metaphor of
Q_MAMODE has been added
to be
implemented
in next
version
CR043 04.06.13 EasyBalise/V13 The name if the radio message has been added
in the listbox
implemented
in version 1.4
CR042 04.06.13 EasyBalise/V13 Unit “Meter” has been added to the Q_LOCACC
variable
implemented
in version 1.4
CR041 17.10.12 EasyBalise/V13 In the packets 12 and 15, the following bugs
have been found:
1. Then unit of the variables L_Section and
D_DP are not displayed properly
2. The Values 126 and 127 of
V_RELEASEDP and V_RELEASEOL can‘t
be selected
3. The labels of V_RELEASEDP and
V_RELEASEOL are wrong (starting with
Q_... is not correct.
implemented
in version 1.4
CR040 16.09.11 EasyBalise/V12 In the packet 76, the variables Q_TEXTREPORT
and NID_TEXTMESSAGE are not properly
allocated to a Metaphor in the LOG-listing. This
shall be corrected in the next version
implemented
in version 1.3
CR039 16.09.11 EasyBalise/V12 In the Packet 27 editor the variable V_DIFF
sometimes s not properly disabled when it is not
possible to modify it. This has to be corrected
with
the next version
implemented
in version 1.3
CR038 16.09.11 EasyBalise/V12 In the Packet 72 the interpretation of the
variable
M_MODETEXTDISPLAY is not correct when
M_VERSION >16. This has to be corrected with
the next version
implemented
in version 1.3
CR037 16.09.11 EasyBalise/V12 In the telegram list of EasyBalise the variable
Q_MAMODE is not decoded properly for packet
80. This needs to be corrected in the next
version
implemented
in version 1.3
CR036 07.09.11 EasyBalise/V12 In the current versions it was not possible to set
V_MAMODE to 127 (use of national value). Now
this has been corrected by adding a
corresponding checkbox.
implemented
in version 1.3
CR035 20.12.10 EasyBalise/V12

and Libraries of
all other Tools
Wrong Decoding of packet 203 has been
corrected
implemented
in version 1.3
CR034 23.10.10 EasyBalise/V12

and Libraries of
all other Tools
After editing and returning the main screen, it
can happen that t the total number of Userbits is
more than 830. In this case the application is
hanging. Although there is a warning message
“Telegram too long” the user can not retrieve
the old data and ignore the change. The
program is abruptly aborted. Userdata and
packetlist are lost.
The change is to give a warning to the user,
ignore the new data and prevent the application
of being aborted uncontrolled
implemented
in version 1.3
CR033 28.08.10 EasyBalise/V12

and Libraries of
all other Tools
Update of ETCS Variables published by ERA

Published on: 28 June 2010 Version: 1.2
Published by: ERTMS Unit
implemented
in version 1.3
CR032 05.05.10 EasyBalise/V11

and Libraries of
all other Tools
During the generation of the Logfile, some
variables can have different meanings according
to M_VERSION. This was not interpreted
correctly in the EasyBalise Version V11.
These variables are not implemented as a
function of M_VERSION (ver).
implemented
in EasyBalise
version 1.2
CR031 05.05.10 EasyBalise/V10
and Libraries of
all other Tools
In the generation of the Logfile the Metaphor for
"NC_CDDIFF" was derived from the definition of
NC_DIFF (instead of NC_CDDIFF). The same for
"NC_CDTRAIN" which was derived from
NC_TRAIN (instead of NC_CDTRAIN).
implemented
in EasyBalise
version 1.2
CR030 05.05.10 ZUBLight 1.0
BaliseLight1.0
TBL1Light1.0
The new Psion Workabout pro G2 delivered with
the TPG of Siemens has an additional built-in
serial interface with the COM-Number “0”. When
the program starts up it shows this “COM0”. The
interface to be connected with the Siemens TGP
is still COM1. So the user has to switch the COM
from 0 to 1 each time the program is started.
To make the program more user friendly, the
program shall always switch to COM1 after
startup (if there is really a COM1 available).
implemented
in ZULight,
BaliseLight,
and
TBL1Light
version 1.1
CR029 05.05.10 EasyBalise/V11
Also in Logdata
of all other Easy
and Light -Tools
Implementation of EuroRadio Messages
decoding. Also all Train to Track packets are
now available for decoding. Radio messages can
be generated like Balise telegrams and loop
messages.
implemented
in EasyBalise
version 1.2
CR028 01.04.10 EasyBalise/V11 In the mainscreen, with version 1.1 it is not
possible to open packet 21 when M_VERSION is
less than 17. This was due to a wrong inside
Version check and has been corrected. Work
around: Open the packet with the drop down
menu and copy the hex data manually.
implemented
in EasyBalise
version 1.2
CR027 01.04.10 EasyBalise/V11 In the packet 15 Editor, some “unit” labels are
not changing automatically according to
Q_SCALE. This has been improved
implemented
in EasyBalise
version 1.2
CR026 17.03.10 EasyBalise/V11 A new menu was create in the “Extra” folder to
create an file association with the Easy Balise
Application an *.tlg Files. It makes automatically
the following changes in the registry: With
double clicking tlg files, EasyBalise is
automatically startet and the corresponding tlg
file is loaded.
aimplemente
d
in EasyBalise
version 1.2
CR025 17.03.10 EasyBalise/V11 The EasyBalise MainScreen has been extended
with a tooltip on most of the controls, labels and
textboxes. When passing the mouse over the
controls, labels and textboxes, a hint is shown
explaining the corresponding item. Showing the
hint can be disabled by a special checkbox on
the
mainscreen.
implemented
in EasyBalise
version 1.2
CR024 11.03.10 EasyBalise/V11

Also in Logdata
of all other Easy
and Light -Tools
Depending on the variable Q_MEDIA, the Header
is either decoded as a LoopHeader or as a
BaliseHeader. In the previous versions, only
decoding of Balise Header was possible
regardless of the status of Q_MEDIA. With this
change, the Tool now is also able to deal with
any kind of Loop message
implemented
in EasyBalise
version 1.2
CR023 12.12.09 EasyBalise/V11
and Libraries of
all other Tools
New Packets 52, 64, 69 88 and 143 for SRS
3.0.0. implemented
implemented
in EasyBalise
version 1.2
CR022 12.12.09 EasyBalise/V11
and Libraries of
all other Tools
Packets 3, 27, 44, 51, 72 und 76 extended in
accordance to SRS 3.0.0
implemented
in EasyBalise
version 1.2
CR021 11.11.09 EasyBalise/V10

Also in Logdata
of all other Easy
and Light -Tools
For the variable L_MAMODE in Packet 80 and the
D_LOOP in Packet 134 and NID_RADIO in Packet
42 the special value “32767” could not be set by
a separate checkbox. This feature shall be
implemented in future version. Also the logfile of
data read by a balise reader shall interpret this
special value
implemented
in version 1.1
CR020 11.11.09 EasyBalise/V10

Also in Logdata
of all other Easy
and Light -Tools
For the variable D_VALIDNV the special value
“32767” could not be set by a separate
checkbox. This feature shall be implemented in
future version. Also the logfile of data read by a
balise reader shall interpret this special value
implemented
in version 1.1
CR019 11.11.09 EasyBalise/V10

Also in Logdata
of all other Easy
and Light -Tools
For the variable D_CYCLOC the special value
“32767” could not be set by a separate
checkbox. This feature shall be implemented in
future version. Also the logfile of data read by a
balise reader shall interpret this special value
implemented
in version 1.1
CR018 11.11.09 EasyBalise/V10 In packets 72 and 76 the variable D_Textdisplay
can be set to a special value “display of text
shall not be distance limited” then value is
32767. In version 1.0 there was implemented a
wrong value, namely 1111.
implemented
in version 1.1
CR017 EasyBalise/V10 In the dialog NID_XUSER=2 of the P44 specific
part of the application, it was not possible to
choose other values for the variable VERSION (8
Bit) than 0 and 1.
The implementation has to be such, that also all
other possible values 2…255 can be selected
without a shutdown of the program.
implemented
in version 1.1
CR016 EasyBalise/V10 In Packet 12, Level 1 movement authority, there
is no relationship betwwn the checkboxes
“unlimited” and the corresponding Time-textbox
(T_LOA, T_ENDTIMER, T_SECTIONTIMERk and
T_OL. The behaviour has to be such that when
the checkbox is checked, the timer (textbox)
shall display 1023 and it shall be disabled. Also if
the user enters 1023 in the textbox, it shall be
disabled and the corresponding checkbox
“unlimited” shall be checked. The same shall
apply between V_MAIN and the checkbox “trop
order” then V_MAIN =0
implemented
in version 1.1
CR015 EasyBalise/V10 If there are two packets with the same packet
number in a telegram, there is no possibility to
modify and safe each of them separately. After
leaving the editor ot the packet, it overwrites
always the same. Also if the editor is opened
with the "open" dialog for a new packet and
when at the same time there is already such a
packet in the telegram, it creates not a new one
but overwrites the existing.
There is a change necessary that packets of the
same type within a telegram can be edited
separately and there shall no limitation
regarding duplication of packets in a telegram.
implemented
in version 1.1
CR014 EasyBalise/V10 The main screen has been optimized.
New title of textboxes with the telegram data
Save TLG File shifted from the left to the right
side of the screen.
New Explanation of the definition of N_PIC (in
red)
Directory for logdata and TLG files are saved
separately in the system settings.
implemented
in version 1.1
CR013 EasyBalise/V10 The dialog to save the logfile is not displayed
after the first reading process, although the
corresponding checkbox is checked.
implemented
in version 1.1
CR012 EasyBalise/V10 After reading a balise the dropdownlist “Test
telegram” is not cleared. This is confusing
implemented
in version 1.1
CR011 EasyBalise/V05
EasyZUB/V05
BaliseLight/V02
ZUBLight/V05
Additional dialog to save data in the csv format implemented
in version 1.0
CR010 ZUBLight/V05 New checkbox "show dialog compare TLG
Master"
implemented
in version 1.0
CR009 ZUBLight/V05
BaliseLight/V02
New startscreen implemented with checkbox
"show dialog compare TLG Master"
implemented
in version 1.0
CR008 EasyZUB/V05
ZUBLight/V05
Pictogramm für Kontrolllicht Bahnübergang
implemented
implemented
in version 1.0
CR007 EasyBalise/V05
BaliseLight/V02
New Packet 40 implemented according to SRS
3.0
implemented
in version 1.0
CR006 EasyBalise/V05
BaliseLight/V02
New Packet 13 implemented according to SRS
3.0
implemented
in version 1.0
CR005 EasyBalise/V05
BaliseLight/V02
New Packet 2 implemented according to SRS 3.0 implemented
in version 1.0
CR004 EasyBalise/V05
BaliseLight/V02
The values M_LEVELTEXTDISPLAY = 5, "The
display of the text shall not be limited by the
level" and M_MODETEXTDISPLAY = 15, "The
display of the text shall not be limited by the
mode". can not be displayed. Presentation of
Packet 72 or 76 can crash.
implemented
in version 1.0
(0.502 SBB)
CR003 EasyZUB/V05
ZUBLight/V05
The status of SIGNUM should also be displayed
on the main screen when GRK > 3. (testing of
level crossing functionality)
implemented
in version 1.0
CR002 EasyBalise/V0.5 A quick preview of the status of all variables
should be available like on the PDA applications
implemented
in version 1.0
CR001 EasyBalise/V05
EasyZUB/V05
BaliseLight/V02
ZUBLight/V05
Decoding Packets with NID_XUSER=2 is logging
the status of the TPR (Prüfbit) instead of the
variable PROV
implemented
in version 1.0

Home | ETCS Tools | Support | Site Map